085 – Waiting for Right Fetcher Out reed switch to be on.

Note: This code occurs when the Reset Bundle button was pressed while the Fetcher cylinders were extended or partially extended. In order to properly reset, the machine will fully extend the Fetcher cylinders (unless they are already extended). The machine will then wait until the Right Fetcher magnet is in front of the Right Fetcher Out reed switch.

If the Right Fetcher cylinder is fully extended,

– Check the air gap distance between the Right Fetcher Out reed switch and the magnet. The distance should be a maximum of 1/8 inch (3 mm). If it is within the suggested range then the reed switch needs to be replaced.

If the Right Fetcher cylinder is partially extended,

– Check that a foreign object is not preventing the Right Fetcher cylinder from extending.

– Electric power or hydraulic power or hydraulic return has been disconnected or shut off from machine.

– Remove and observe the Fetcher check valve. If the snap ring in the bottom of the check valve is missing then the check valve needs to be replaced. If you are unable to push the plunger from the end of the check valve in and it spring back, then the check valve needs to be replaced.

If the Right Fetcher cylinder is still retracted,

– Check that hydraulic power is still on to the machine and that return line is still connected.

– Check that a foreign object is not preventing the Right Fetcher cylinder from extending.

– Remove and observe the Fetcher check valve. If the snap ring in the bottom of the check valve is missing then the check valve needs to be replaced. If you are unable to push the plunger from the end of the check valve in and it spring back, then the check valve needs to be replaced.

– Check that the directional valve is not stuck.